types of mcbs

Last Updated on April 16, 2024 by Jawad Ali

Introduction to MCB

An MCB (Miniature Circuit Breaker) protects an electrical circuit from over currents through electromechanical means. An electrical circuit can have an over current if short-circuited, overloaded, or miss designed.

MCBs are used to protect against over currents and short circuits. This type of device is commonly found in residential and commercial settings.

Similarly, we check appliances like washing machines and refrigerators thoroughly before purchasing them, and we should also research miniature circuit breakers.

MCBs are more practical than fuses, requiring no replacement once an overload is detected. An MCB is more convenient to operate than a fuse and can offer more excellent operational safety and greater convenience without requiring a lot of maintenance. Low current circuits are protected using MCBs, consisting of the following features. This guide is all about types of Mcbs and all other info.

Types of MCBs

In addition, to types A, B, C, D, K, and Z, there are five other types of MCB. It is important to note that there are three main types: type B, type C, and type D. These are designed differently based on the likelihood that electrical surges will occur in different locations. They are commonly called a ‘trip curve’ or a ‘tripping characteristic’; however, they can also be called a ‘tripping characteristic’.

Miniature Circuit Breakers, or MCBs, are electrical devices that protect electrical circuits from overcurrents, short circuits, and other electrical faults. There are several different types of MCBs, each with unique features and applications. One type of MCB is the Type B MCB, designed to protect against overcurrents caused by resistive loads. Another type of MCB is the Type C MCB, designed to protect against overcurrents caused by inductive loads, such as motors and transformers. The Type D MCB is designed to protect against overcurrents caused by equipment with high inrush currents, such as fluorescent lighting and air conditioners. The Type K MCB is used to protect against overcurrents in photovoltaic systems.

Listed below are the differences between each of the primary types:

1.      Type B

When the current flowing through a Type B circuit breaker reaches three to five times the maximum capacity prescribed, the circuit breaker trips.

A low voltage commercial setting, low voltage domestic applications, or other applications where there may be small current surges will benefit from this type of MCB.

2.      Type C

Electrical circuit breakers of Type C are used for devices with more significant amounts of power, which are more likely to experience more significant surges. These are generally found in commercial and industrial settings.

Read more:Car Exterior Detailing: Each And Everything You Need To Know

Designed to trip at currents up to 150% of their rated load, they trip at currents between five and ten times their rated load. Fluorescent lighting and electric motors are excellent examples.

3.      Type D

The D-type MCB is the least sensitive type, only triggering when the current surges between ten and twenty times the standard level.

These MCBs are designed for heavy-duty commercial and industrial applications where there are occasional surges of a powerful current. There are welding equipment, X-ray machines, large motors, and uninterruptible power supplies, to name a few.

4.      Type K               

The trip points will be triggered when the current reaches eight to twelve times the maximum recommended value.

5.      Type Z

In this class, MCBs are highly sensitive, tripping when the current exceeds the rated load by two to three times. Often they are used with more delicate devices, such as semiconductors, that can fail due to short circuits.

Working of MCB

As a rule, and under normal circumstances, the MCB acts as a switch (a manual switch) to turn a circuit on or off. The device trips when a short circuit occurs or when there is an overload. A current interruption occurs in the load circuit, which corrects the problem. During a trip, the operating knob automatically moves to the OFF position to indicate the end of the trip.

MCBs can be tripped automatically in two different ways: magnetically or thermally. Whenever a bimetal is overloaded, its temperature rises due to the current flowing through it. The heat generated by the rising temperature within the bimetal causes the bimetal to deflect.

 The expansion of metals causes this to occur. Consequently, the trip latch is released, and the contacts are separated. A magnetic field created by the coil creates a force that pulls the bimetal, causing a deflection that activates the tripping mechanism in other MCBs.

Most MCBs are tripped by a combination of thermal and magnetic tripping mechanisms. Both mechanisms cause an arc to form when the contacts separate. An arc runner then forces the arc into an arc splitter. ARC splitter plates and arc chutes are referred to as arc splitter plates. A series of arcs is formed when energy and cooling are extracted from an arc. In this way, arcs are removed from the arrangement.

How to choose the right MCB?

In residential, commercial, industrial, or public buildings, there are several simple rules for selecting whether to use Type B, C, or D miniature circuit breakers for final circuit protection. After learning about the different MCB kinds, you should consider which would work best for your household device. Learning a few technical pieces of information is crucial before choosing the type of MCB. Check the voltage and frequency at which the device operates first, as well as if it is an AC or DC device.

The installer must be aware of the differences between these types of equipment to avoid tripping or make an appropriate selection where demarcation lines are less clear.

The primary purpose of circuit protection devices is to protect the cable downstream of the device, as opposed to miniature circuit breakers and fuses.

It is critical to compare the ability of Type B, C, and D devices to handle surge currents without tripping. Typically, these currents are accent or other discharge lighting, induction motors, battery chargers, etc.

Applications of MCB

·         A mechanism for ground fault trips

When used in conjunction with a ground fault or arc fault mechanism, a miniature circuit breaker can be utilized efficiently. If a live wire contacts a transmitter surface outside of the circuit system, a ground fault will occur. An overcurrent will increase the current flow rate if there is a fault in the circuit. In the event of an MCB trip, the magnetic tripping mechanism activates and corrects the circuit.

By installing miniature circuit breakers correctly, you can ensure the safety of all electrical systems throughout the home and in workplace.

·         Applied to industries

Whether used in small or large-scale industries, miniature circuit breakers can provide reliable safety. The typical power supply requirement for most machinery in industries is up to 30 kA. MCBs should be used instead of old fuses if this is the case.

The main functions of MCBs in commercial establishments are to maintain the efficiency of applications and installations by optimizing the flow of electricity. Hotels, supermarkets, and bakeries are examples of establishments that use them extensively.

Benefits of MCB over Fuse

Fuse and MCB are both devices that protect against power surges. However, MCBs have the following advantages:

  • It is reusable when the circuit has been interrupted due to overload or a short circuit. An MCB will reset after the fault has been corrected, while fuses need to be rewired or replaced.
  • Offers a safer method of terminating short-circuits current and arc quenching.
  • Provides better protection against overload than fuses.
  • These fuses can be turned off whenever they are needed. Therefore, MCBs make circuit isolation during maintenance much more accessible than fuses do.
  • At the same time, the fuse wire should be checked by opening the fuse grip or opening the hole from the fuse base.
  • As a result, MCBs are very sensitive to faults compared to fuses.
  • When a short circuit occurs, they respond faster than fuses.
  • MCBs are safer to handle electrically than fuses.